Check 3 of 4 · Site Checker
Check before factory-plan submission
Verify that the proposed factory-plan pack accurately reflects the site and agreed design before submission.
Site Checker must have before travellingYour responsibility · 7 items
Check type and scope confirmed before booking.
More detail
Know which of the four checks this is and which rooms or areas are included.
Latest issued revision only — no superseded drawings mixed in.
More detail
Check revision references match across every sheet in the pack.
Review the pack before travelling.
More detail
Missing critical information goes back to the consultant before attendance, or before the affected work proceeds.
Latest proposed factory plans, elevations and sections/details.
Revision list showing changes since the previous check.
Earlier measurement records and site photographs.
List of remaining approvals and uncertainties.
Site Checker on site: measure, inspect, mark, verifyYour responsibility · 7 items
Key dimensions against the site and previous measurement records.
Wall runs, heights, openings, bulkheads and finished-level assumptions.
Cabinet fit, fillers, scribes, panels, opening clearances and appliance spaces.
Service positions against the proposed factory plans.
Whether building changes have invalidated earlier measurements.
Whether earlier discrepancies were corrected throughout the pack.
More detail
Check every affected sheet, not only the one where the error was first found.
Areas not yet verifiable and assumptions affecting manufacture.
Photographs and measurements to captureYour responsibility · 4 items
Re-measured key dimensions recorded against plan references.
Photos of any area where conditions changed since the last check.
Photos of service positions relative to the planned cabinetry.
Unverifiable areas and manufacturing assumptions listed explicitly.
Matters requiring clarificationYour responsibility · 4 items
Differences between factory plans and site measurements.
Earlier corrections not carried through the whole pack.
Remaining client approvals or unconfirmed specifications.
Assumptions about finished levels or unfinished work.
Resolve before progressingYour responsibility · 5 items
The Site Checker identifies and returns discrepancies.
The design assistant revises the drawings.
The responsible consultant checks decisions and corrections are incorporated.
Recheck affected areas where necessary.
Follow TKS's authorised factory-release process.
Consultant providesDesign Consultant · 4 items
Final proposed design and confirmed client decisions.
Approved specifications and appliance details.
Previous site-check findings and agreed changes.
Clear identification of remaining approvals or uncertainties.
Design assistant preparesDesign Assistant · 6 items
Latest proposed factory plans, elevations and relevant sections/details.
Cabinet sizes and positions, fillers, scribes, end panels and finish details.
Appliance openings and manufacturer requirements.
Coordinated plumbing/electrical information.
A revision list showing changes since the previous check.
References to earlier measurements and site photographs.